VARIABLE FREQUENCY DRIVES: SELECTION AND ACCEPTANCE Yenra | Updated September 11, 2026 Article: https://yenra.com/variable-frequency-drive/ Purpose: assemble a drive selection brief with the responsible electrical and process engineers. Use: complete the load and duty fields first; record unknowns as UNKNOWN. Supplier-approved limits and the actual machine documentation govern installation and commissioning. EQUIPMENT AND LOAD Asset / location / owner: Motor model / nameplate photo / rated current A / rated power kW / voltage V / frequency Hz / speed rpm: Supply phase / voltage V / available electrical design record: Driven equipment / torque behavior / starting load / overload duration s: Process output and units / minimum and maximum required service: Speed range / motor cooling assessment / stopping and braking needs: Cable length m / route / enclosure / ambient temperature deg C / altitude m: Drive continuous current and overload rating at this duty / supplier evidence: Motor insulation, bearing-current and cable mitigation assessment owner: Command interfaces / loss-of-command response / restart response: ENERGY COMPARISON (electrical INPUT power at equivalent useful service) For each operating point: service condition | annual hours h | existing kW | proposed kW | evidence 1. 2. 3. Sum hours; avoid overlapping operating periods. For each system, sum(kW * hours) = kWh/year. Fictional check: existing 12 kW * 4,000 h = 48,000 kWh/year. Proposed: 12.5 kW * 1,000 h + 5 kW * 3,000 h = 27,500 kWh/year. Difference 20,500 kWh/year. Invented energy-only $0.12/kWh gives $2,460/year. The full-demand penalty is included. These are teaching inputs, not a performance prediction. Installation, demand charges, taxes, maintenance and process changes are separate. Your energy-only rate and source / excluded costs / sensitivity to operating hours: ACCEPTANCE Operating point | required flow/pressure/other output and units | power measurement method | duration | limits and source | result: Approved tests for command loss, sensor failure, trip, stopping and restoration: Reviewer / exceptions / approved parameter file / firmware / drawings / date: Recheck after motor, cable, load, duty-cycle or process-limit changes. PRIMARY REFERENCES part-load efficiency guide https://www.energy.gov/sites/prod/files/2014/04/f15/motor_tip_sheet11.pdf motor and drive systems sourcebook https://www.energy.gov/sites/prod/files/2014/04/f15/amo_motors_sourcebook_web.pdf motor–drive interaction guide https://www.energy.gov/sites/prod/files/2014/04/f15/motor_tip_sheet15.pdf