USB I/O — LOAD AND STATE TEST RECORD Plan low-voltage bench checks using the exact device manual. This form does not authorize mains work or safety-critical control. Module model / hardware revision / serial / manual URL and version: Driver / firmware / host OS / USB hub and cable: Output topology / terminal map / external supply needed: Load type / supply min-max V / normal A / inrush A and duration: Inductive suppression method / manufacturer reference / release-time effect: On resistance or drop / off leakage / channel and total limits: Isolation function and ratings / source section: Required inactive state / reason / feedback signal: Illustrative only: 12 V, 1000-ohm 0.5 W resistor, 1-ohm switch -> I = 12/1001 = 0.01199 A; resistor power about 0.144 W; switch drop about 0.012 V. Check actual ratings and derating. For every test write required state, observed physical state, delay, pass/fail, evidence file: 1. Power before software: 2. On and off commands: 3. Normal application close: 4. Application failure: 5. USB cable loss: 6. Hub power loss: 7. Reconnection and reinitialization: 8. Other outputs unchanged during a command: Readback meaning: register / actual output / independent load sensor: Unmet requirement / hardware or software corrective action / retest: Yenra | Updated September 10, 2026 Article and explanation: https://yenra.com/usb-data-acquisition/module.html Source references (use exact equipment/material documents for actual work): https://digilent.com/shop/mcc-usb-erb-series-electromechanical-relay-usb-devices/ https://files.digilent.com/manuals%2FUM9810-17.pdf https://files.digilent.com/manuals/USB-ERB08.pdf