YENRA WORKSHOP LOAD RECORD (U.S.) Guide: https://yenra.com/powerstrip/ Purpose: collect information for selection or discussion with an electrician. This record does not approve a circuit, installation or equipment combination. Copy into a text editor and use input ratings for the intended supply voltage. Date / location: Power strip model / certification / manual: Total strip rating / supply voltage / environmental rating: Permitted equipment / mounting instructions: Wall receptacle / known branch circuit / other loads on that circuit: Required protection confirmed by: Device | AC input volts | AC input amps | Runs with others? | Manual limits | | | | | | | | | | | | Use AC INPUT ratings, not battery capacity or charger output. Obtain input-current data when needed; watts/volts alone may be insufficient for motors and electronic loads. Identify startup and duration constraints. Illustrative simultaneous inputs: 1.2 A + 1.0 A + 0.3 A = 2.5 A. Recorded simultaneous total: Other circuit loads / startup demand / duration / unresolved questions: Checks before use: - Product and connected equipment instructions permit the arrangement. - Ordinary relocatable tap connects directly to a suitable wall receptacle; no other strip or extension cord feeds it. - Cord and plugs intact; grounding preserved; cord protected from damage. - Location rating, ventilation and required protection are appropriate. - Unknown circuit capacity or repeated trips referred to an electrician. Recheck whenever equipment changes. Stop use for damage, scorching, unusual heat, odor or sparking; resolve the cause rather than repeatedly resetting. UL selection guidance: https://www.ul.com/insights/guide-power-strips-and-surge-protectors