DC-DC CONVERTER REQUIREMENTS AND VERIFICATION RECORD Yenra | Updated September 7, 2026 Article: https://yenra.com/power-converter/ PURPOSE Record requirements for a DC-DC module and the evidence a qualified electronics designer will verify. Use exact part numbers and document revisions. This is not a wiring, mains-design or safety-approval guide. APPLICATION Load and required function: Input source: Module ordering code and options: Data sheet revision and source: Application environment and relevant product requirements: INPUT AT MODULE TERMINALS Minimum / nominal / maximum normal voltage (V): Cable and source drop assumptions: Startup / brownout / transients and duration: Source filtering and impedance conditions: Do not use absolute-maximum stress limits as operating targets. OUTPUT AND ISOLATION Required voltage and tolerance (V): Steady / peak current (A) and peak duration: Load-step and startup requirements: Permitted output capacitance and load behavior: Isolation purpose, working voltage and applicable approval evidence: Ripple limit, bandwidth and measurement method: POWER AND LOSS Output power W = output V x output A. Input power W = output W / efficiency as a fraction. Converter loss W = input W - output W. Average input current A = input W / input V. FICTIONAL EXAMPLE: 5 V x 8 A = 40 W output. At .90 efficiency: 44.44 W input, 4.44 W loss. At 24 V input: about 1.85 A average input current. At .85 efficiency: 47.06 W input and 7.06 W loss. These rounded values exclude other system losses and do not predict startup, ripple or peak currents. THERMAL EVIDENCE Efficiency curve and actual input/load/temperature point: Derating curve and exact cooling assumptions: Airflow / orientation / enclosure / ambient: Baseplate or component temperature limit and method: Neighboring heat sources and worst credible operation: Required heat path and validation evidence: Do not transfer thermal data from an unrelated mounting arrangement. VALIDATION RECORD Board/layout and component revisions: Instruments and methods: Startup / regulation / load step acceptance criteria: Temperature / fault / recovery acceptance criteria: Current limit, hiccup, latch or thermal response expected: Measured results and raw evidence location: Open issue / responsible designer / action: Final disposition and document revision: Validate the complete source, filter, converter and load together. REFERENCE CONTEXT The linked article explains the comparisons and limits. Check exact project or equipment documents before using a specification. Guidelines for Testing DC-DC Converters https://s3.us-east-2.amazonaws.com/synqor/resources/an_Guidelines%20for%20Testing%20SynQor%20DC-DC%20Converters.pdf Texas Instruments’ TPSM53604 data sheet https://www.ti.com/lit/ds/symlink/tpsm53604.pdf output-voltage ripple measurement note https://s3.us-east-2.amazonaws.com/synqor/resources/FAE_7_an_Vout_Ripple_Measurement.pdf