SEMICONDUCTOR PARAMETRIC TESTING: BUILD A TRUSTWORTHY MEASUREMENT PLAN Editable planning/verification record — Yenra Updated: October 2, 2026 Article: https://yenra.com/parametric-testing/ Purpose: Specify a DC test with traceable bias, range, compliance, settling and calibration conditions, and recognize when RF methods need a separate setup. Intended reader: Device and process engineers planning wafer-level electrical characterization. HOW TO USE Save a working copy. Enter the actual specification, units, assumptions and evidence references in each field. Preserve original observations and record changes. Have the responsible reviewer resolve missing or conflicting requirements before release. Examples below are fictional teaching inputs, not process settings or acceptance standards. RECORD 1. Wafer/lot/site/device identity, structure and required parameter: ____________________________________________________________ 2. Approved bias sequence, polarity and limits in V/A; temperature in deg C: ____________________________________________________________ 3. Instrument/module, calibration status, firmware and test revision: ____________________________________________________________ 4. Force/sense connections, probes, switching, shielding and guarding diagram reference: ____________________________________________________________ 5. Ranges, integration time, source delay, settling evidence and compliance setting: ____________________________________________________________ 6. Actual sourced/measured values, status flags and raw record location: ____________________________________________________________ 7. Control/blank results, leakage/drift investigation and uncertainty: ____________________________________________________________ 8. Pass/fail decision rule, exceptions, review and requalification triggers: ____________________________________________________________ WORKED EXAMPLE AND LIMITS Fictional leakage observation under one approved fixed bias: current is 32 pA after 0.1 s, 14 pA after 1 s and 12 pA after 5 s. This indicates time dependence in the combined DUT/setup response. It does not establish 5 s as sufficient settling for every device or justify subtracting a fixture blank without a validated correction. Repeat and investigate using the applicable test procedure. REVIEW Prepared by / date: ____________________ Reviewed by / date: ____________________ Open issues, responsible owner, due date: ____________________ Approved next action and evidence: ____________________ SOURCE CONTEXT These primary references support the linked article. Use exact applicable product, contract, and document versions for operational work. Keysight's parametric-test handbook https://www.keysight.com/us/en/assets/7018-05884/application-notes/5992-2508.pdf Keysight E5270B quick reference https://www.keysight.com/us/en/assets/9018-07953/quick-start-guides/9018-07953.pdf Keithley's Low Level Measurements Handbook https://www.tek.com/en/documents/product-article/keithley-low-level-measurements-handbook---7th-edition Keithley switching guide https://www.tek.com/en/documents/fact-sheet/e-handbook-guide-switch-considerations-signal-type Return to the guide: https://yenra.com/parametric-testing/