YENRA - CONDUCTIVE FABRIC GASKET FIT RECORD Guide: https://yenra.com/gaskets/conductive-fabric.html Updated: September 16, 2026 Use this record for a specified enclosure revision and candidate part. Dimensional fit is one input to qualification; complete assembly testing against the actual product requirements remains necessary. Project / engineer / date: Enclosure revision / seam location / drawing: Gasket manufacturer / exact part / lot: Part datasheet revision and location: Mating materials / finishes / surface preparation specification: Attachment / adhesive / intended electrical contact path: Fasteners / spacing / closing-force limit: Temperature / moisture / expected opening cycles: Frequency range / EMC target / applicable test method: DIMENSIONS - millimeters Free gasket height nominal h: Free height tolerance / minimum / maximum: Closed gap nominal g: Closed gap minimum / maximum / measurement locations: Nominal compression = (h - g) / h x 100 percent: Minimum and maximum compression including height and gap tolerances: Allowed working compression and source: Force-deflection evidence and source: Illustrative example, holding h fixed at 2.0 mm: g = 1.4 mm -> (2.0 - 1.4) / 2.0 x 100 = 30 percent. g = 1.2 to 1.6 mm -> 40 down to 20 percent. These invented dimensions do not establish an acceptable operating range. QUALIFICATION Closure and deformation result: Corner / join / between-fastener contact assessment: Approved contact evaluation method and result: Reopening or environmental test conditions and results: Assembly EMC configuration / report / result: Other seams, vents, connectors and cable entries included: Exceptions / unresolved issues / next test: Approved by / date: REVISIT WHEN CHANGED Check enclosure finish, gasket part or supplier, adhesive, profile, fastener spacing, dimensions and environmental or electromagnetic targets.