DIGITAL ISOLATION — REQUIREMENTS AND EVIDENCE Use one record per barrier. Have the responsible engineer establish insulation requirements from the applicable product standard; this worksheet supplies no safety rating or clearance value. Domain A ground / supply / function: Domain B ground / supply / function: All conductive paths reviewed (power, shield, debugger, USB, hardware): Required insulation function / standard and edition / reviewer: Working voltage (RMS/DC and/or repetitive peak; include waveform): Withstand test voltage / duration / standard: Surge requirement / waveform: Creepage / clearance / material / pollution / altitude requirements: CMTI minimum (kV/us) / actual common-mode conditions: Part / exact suffix / package / certificate references: Channel counts and directions / local supply ranges / thresholds: Default outputs during missing power, floating input and reset: Isolated power arrangement / startup / current budget: Timing mode / launch edge / capture edge / maximum delays / margin: Illustrative only: 10 MHz half-cycle = 50 ns; 10 + 18 + 10 + 7 = 45 ns; margin 5 ns. At 20 MHz, 25 - 45 = -20 ns. Replace values with guaranteed limits and uncertainty. Validation evidence: hardware / firmware / supply / temperature / patterns: Startup and missing-side power tests: Qualified compliance tests required / owner / results: Each specification: value / units / min-typ-max / source section / open issue. Yenra | Updated September 10, 2026 Article and explanation: https://yenra.com/digital-voltage-isolation/ Source references (use exact equipment/material documents for actual work): https://www.ti.com/lit/pdf/slla284 https://www.ti.com/lit/ab/slla426/slla426.pdf https://www.ti.com/product/ISO6463